Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Arch Ital Urol Androl ; 96(1): 12228, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38363229

RESUMO

PURPOSE: The aim of the present, retrospective study was to describe our initial experience and early outcomes of Thulium Fiber Laser enucleation of the prostate (ThuFLEP) with the use of the FiberDust™ (Quanta System, Samarate, Italy) in patients with benign prostate hyperplasia. METHODS: From June 2022 to April 2023, all patients who underwent endoscopic enucleation of the prostate at Urology Department of the University Hospital of Patras were included. A single surgeon utilizing the same standardized operative technique performed all the surgeries. The primary endpoints included the uneventful completion of the operation, the surgical time and any minor or major complication observed intra- or post-operatively. RESULTS: Twenty patients with benign prostate hyperplasia were treated with ThuFLEP. All the surgeries were completed successfully and uneventfully. The enucleation phase of the operation was completed in a mean time of 45±9.1 min, while the average time needed for the morcellation was 17.65±3.42 min. No significant complications were observed intra- or post-operatively. The average hemoglobin drop was calculated to be 0.94±0.71 g/dL. CONCLUSIONS: All the operations were successfully and efficiently completed with the use of the FiberDust™ (Quanta System, Samarate, Italy) in ThuFLEP. Significant blood loss or major complications were not observed.


Assuntos
Terapia a Laser , Lasers de Estado Sólido , Hiperplasia Prostática , Ressecção Transuretral da Próstata , Masculino , Humanos , Próstata/cirurgia , Estudos Retrospectivos , Túlio , Hiperplasia , Resultado do Tratamento , Lasers de Estado Sólido/uso terapêutico , Hiperplasia Prostática/cirurgia , Ressecção Transuretral da Próstata/métodos
2.
Arch Ital Urol Androl ; 96(1): 12248, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38389459

RESUMO

PURPOSE: The aim of this study is the evaluation of the distribution of paclitaxel (PTX) released by a coated balloon in the layers of rabbit's urethra. METHODS: 18 rabbits were included. A laser device was used for the stricture formation. After two weeks, dilation of the strictured urethra was performed by using Advance 35LP PTA balloons and Advance 18 PTX PTA balloons. The experimental models were divided into 3 groups. The group Α included two rabbits without any intervention except for the stenosis procedure. Group B compromised six rabbits that underwent dilation with Advance 35LP PTA balloons. Group C consisted of 10 rabbits to which dilation with both Advance 35LP PTA balloons and Advance 18 PTX PTA balloons was applied. Histological evaluation and Immunohistochemistry were performed on all specimens. RESULTS: Inflammation, fibrosis and ruptures were detected in the specimens of the study. In specimens of Group C the decrease of inflammation and fibrosis rate was greater. Anti-PTX antibody was detected in the epithelium, lamina propria and smooth muscle layer of all specimens of urethras that have been harvested immediately and 1 day after the dilation with Advance 18 PTX PTA balloon and it was not observed in any layer of the urethral wall of the rest of the examined specimens of Group C. CONCLUSIONS: PTX's enrichment was detected in the smooth muscle layer of all specimens that have been harvested immediately and 24h after the dilation with Advance 18 PTX PTA balloons. PTX may play an inhibitive role in the recurrence of the stenosis.


Assuntos
Estreitamento Uretral , Animais , Coelhos , Estreitamento Uretral/terapia , Paclitaxel , Uretra , Constrição Patológica , Fibrose , Inflamação
3.
Int Urol Nephrol ; 56(5): 1577-1583, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38175386

RESUMO

PURPOSE: To investigate the learning curve in four basic surgical skills in laparoscopic and robotic surgeries, and evaluate the approximate time needed to reach sufficient expertise in performing these tasks with the avatera® system. METHODS: Twenty urology residents with no previous experience in dry-lab and robotic surgery were asked to complete four basic laparoscopic tasks (peg transfer, circle cutting, needle guidance, and suturing) laparoscopically and robotically. All participants were asked to complete the tasks first after watching the Uroweb educational material and, second, after undertaking a 2-hour training in robotic and laparoscopic dry-lab. Thereafter, all trainees continued to undertake 2-hour training programs until being able to complete the tasks with the avatera® robot at the desired time. Paired t test and one-way ANOVA test were used to analyze time differences between the groups. RESULTS: Time needed to complete all tasks either robotically or laparoscopically was significantly less in the second compared to the first attempt for all Groups in each Task. In the robotic dry-lab, time needed to complete the tasks was significantly less than in the laparoscopic dry-lab. A significant effect of previous laparoscopic experience of the participants on the training time needed to achieve most of the goal times was detected. CONCLUSION: The results of the study highlight the role of previous laparoscopic experience in the training time needed to achieve the performance time goals and demonstrate that the learning curve of basic surgical skills using the avatera® system is steeper than the laparoscopic one.


Assuntos
Laparoscopia , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Competência Clínica , Robótica/educação , Laparoscopia/métodos , Curva de Aprendizado
4.
Urology ; 183: 106-110, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37981058

RESUMO

OBJECTIVE: To evaluate retrospectively the feasibility of Florence robotic intracorporeal neobladder technique in laparoscopic radical cystectomy. METHODS: Fourteen patients with muscle-invasive bladder cancer underwent laparoscopic radical cystectomy and Florence robotic intracorporeal neobladder between September 2021 and February 2023. Patients' characteristics, pathology data, perioperative outcomes, postoperative complications, and follow-up data were collected. RESULTS: All operations were successfully completed laparoscopically. The median total operative time was 343 minutes, and the median estimated blood loss was 169.5 mL. No intraoperative complications were observed. The median hospitalization time was 7days, while the median time to regular diet was 3days. Clavien Dindo Grade < III complications appeared in five patients within 30days postoperation. No other complications were noted over the 90days follow-up. Organ-confined disease was confirmed in 11 patients and locally advanced disease in three patients. At 3months follow-up, eight and four patients were daytime and night-time continent, respectively. CONCLUSION: Replicating Florence robotic intracorporeal neobladder in laparoscopic radical cystectomy is safe, feasible, and repeatable, based on the encouraging perioperative, oncological, and functional outcomes of our study. However, further prospective studies on a larger scale are required to prove its long-term results.


Assuntos
Laparoscopia , Procedimentos Cirúrgicos Robóticos , Neoplasias da Bexiga Urinária , Derivação Urinária , Humanos , Cistectomia/métodos , Estudos Retrospectivos , Estudos Prospectivos , Resultado do Tratamento , Neoplasias da Bexiga Urinária/patologia , Laparoscopia/métodos , Derivação Urinária/métodos , Procedimentos Cirúrgicos Robóticos/métodos
5.
Minerva Urol Nephrol ; 76(1): 52-59, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38015550

RESUMO

BACKGROUND: Robot-assisted radical prostatectomy is a minimally invasive, safe procedure preferred in the management of localized prostate cancer. In this study, we present our initial experience with the avatera™ system (avateramedical GmbH, Jena, Germany) in robot-assisted radical prostatectomy. METHODS: A total of fourteen patients underwent robot-assisted radical prostatectomy using this newly introduced system in our department from June 2022 to October 2022. The primary endpoints of the study were the time and the successful completion of the operation, the hemoglobin drop and the presence of complications. The pathologic tumor stage and the presence of positive surgical margins were also recorded. Follow-up of the patients for the functional outcomes over a period of 3 months took place. RESULTS: The completion of all the surgeries was successful. The median draping and docking times were 9.5 minutes (7-13) and 10 minutes (5-40), respectively. The median console time was 103.5 minutes (90-121). No conversion to laparoscopic or open prostatectomy was necessary. The median hemoglobin drop was 1.95 g/dL (0.3-2.7), while positive surgical margins were present in two patients postoperatively. No major complications or need for transfusion were noticed. Six months after the procedure, 78.6% of the participants were continent while 77.7% of the nerve-sparing patients reported erections adequate for intercourse. CONCLUSIONS: All the operations were completed successfully without major complications or significant blood loss. The functional outcomes were acceptable according to the literature. Based on the early outcomes, robot-assisted radical prostatectomy with the avatera™ system (avateramedical GmbH) could be considered feasible, safe, and efficient.


Assuntos
Laparoscopia , Robótica , Masculino , Humanos , Projetos Piloto , Margens de Excisão , Estudos Prospectivos , Prostatectomia , Hemoglobinas
6.
Arch Ital Urol Androl ; 95(4): 11852, 2023 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-38058288

RESUMO

PURPOSE: To evaluate the safety and feasibility of partial nephrectomy with the use of the novel robotic system in an in vivo animal model. METHODS: Right partial nephrectomy was performed in female pigs by a surgical team consisting of one surgeon and one bedside assistant. Both were experienced in laparoscopic surgery and trained in the use of the novel robotic system. The partial nephrectomies were performed using four trocars (three trocars for the robotic arms and one as an assistant trocar). The completion of the operations, set-up time, operation time, warm ischemia time (WIT) and complication events were recorded. The decrease in all variables between the first and last operation was calculated. RESULTS: In total, eight partial nephrectomies were performed in eight female pigs. All operations were successfully completed. The median set-up time was 19.5 (range, 15-30) minutes, while the estimated median operative time was 80.5 minutes (range, 59-114). The median WIT was 23.5 minutes (range, 17-32) and intra- or postoperative complications were not observed. All variables decreased in consecutive operations. More precisely, the decrease in the set-up time was calculated to 15 minutes between the first and third attempts. The operative time was reduced by 55 minutes between the first and last operation, while the WIT was decreased by 15 minutes during the consecutive attempts. No complications were noticed in any operation. CONCLUSIONS: Using the newly introduced robotic system, all the advantages of robotic surgery are optimized and incorporated, and partial nephrectomies can be performed in a safe and effective manner.


Assuntos
Neoplasias Renais , Laparoscopia , Procedimentos Cirúrgicos Robóticos , Feminino , Animais , Suínos , Neoplasias Renais/cirurgia , Estudos de Viabilidade , Nefrectomia , Resultado do Tratamento , Estudos Retrospectivos
7.
Cent European J Urol ; 76(3): 233-238, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38045785

RESUMO

Introduction: The aim of this study was to evaluate outflow variation in different locations of the pyelocaliceal system with the use of different ureteral access sheath (UAS) sizes and different UAS positioning. Material and methods: The experimental setup included an anaesthetised porcine model, a 7.5-Fr ureteroscope with a 200-µm laser fibre inserted in the working channel, a hand-held pumping irrigating system, and UAS of different sizes, namely: 9.5/11.5 Fr, 12/14 Fr, and 14/16 Fr. Each UAS was placed just below the ureteropelvic junction (UPJ) or in the mid-ureter. The ureteroscope was placed in the renal pelvis, upper and lower calyces, and outflow measurements were obtained with 3-second interval pumping for one minute in every experimental setup. Results: The UAS positioning in the mid-ureter was associated with significantly higher outflow rates in the lower calyx (p = 0.041). While the UAS was below the UPJ, we observed a trend of lower outflow rate in the lower calyx, which was completely inverted when the UAS was in the mid-ureter. Increasing the UAS size from 9.5/11.5 Fr to 12/14 Fr led to a significant increase in outflow in the renal pelvis and upper calyx (p = 0.007), but not in the lower calyx. A further increase to 14/16 Fr did not produce increased flow. Conclusions: Different locations of the pyelocaliceal system have different fluid mechanics during fURS. In the renal pelvis and upper calyx increasing the diameter of the UAS improved the outflow, whereas in the lower calyx the position of the UAS seems to be the most relevant factor. These variables should be considered when performing fURS, especially with high-power laser lithotripsy.

8.
Urol Res Pract ; 49(6): 387-391, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37971390

RESUMO

OBJECTIVE: To evaluate the tissue injury caused by the force applied by the roboticassisted graspers of avatera robotic surgical system on bowel tissue. METHODS: An experimental in vivo porcine model with 1 pig was conducted. After a standard transperitoneal setup of the avatera robotic surgical system, different laparoscopic and robotic graspers were used on the bowel with maximum force applied each time. Robotic atraumatic grasper, laparoscopic right angle grasper, laparoscopic curved grasper, and laparoscopic atraumatic grasper were used. After using all graspers, the pig was sacrificed. The bowel segments were resected and sent for histological analysis. RESULTS: The pathologist reported that all the graspers caused signs of acute inflammation without any irreversible damage or signs compatible with ischemia of the tissue. No significant difference in histology was observed between the graspers. CONCLUSION: No permanent damage was caused by graspers, except for acute, reversible inflammation. Concluding, the avatera grasper could be safe to use on bowel segments, independent of the applied pressure.

9.
World J Urol ; 41(11): 3155-3160, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37668715

RESUMO

PURPOSE: This pilot study was designed to interpret the technically specific features of the avatera robotic system and present our initial experience with this novel platform in robot-assisted pyeloplasty (RAP). METHODS: A single-center prospective study was conducted including all patients who underwent RAP with the avatera robotic system from June 2022 to October 2022 in our Department. Transperitoneal robot-assisted dismembered pyeloplasty was performed in all cases. The trocar placement and the surgical technique were similar in all patients. The successful completion of the procedures, operation time (including draping, docking and console time), decrease in hemoglobin postoperatively, and presence of any complications were the study's primary endpoints. RESULTS: In total, nine patients underwent RAP using the avatera system. All procedures were successfully completed. The draping of the robotic unit was completed in a median time of 10 min (range 7-15), while the median docking time was 17 min (range 10-24). The median console time was 88 min (range 78-116) and no complications were noticed. The median hemoglobin drop was calculated to 0.7 g/dL (range 0.4-1). During the mean follow-up of 9.33 ± 2.78 months, no late postoperative complications were noticed. CONCLUSION: The early outcomes of the use of the novel avatera system in RAP are presented. All operations were successfully completed with safety and efficacy, without complications or significant blood loss.


Assuntos
Laparoscopia , Procedimentos Cirúrgicos Robóticos , Robótica , Obstrução Ureteral , Humanos , Robótica/métodos , Estudos Prospectivos , Projetos Piloto , Resultado do Tratamento , Obstrução Ureteral/cirurgia , Procedimentos Cirúrgicos Urológicos/métodos , Hemoglobinas , Laparoscopia/métodos , Pelve Renal/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos
10.
Cent European J Urol ; 76(1): 44-48, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37064255

RESUMO

Introduction: The aim of this study was to evaluate the possible histopathological alterations that occur in the kidneys due to a continuous temperature increase above 43°C for one hour of lithotripsy using a newly introduced thulium fiber laser (TFL). Material and methods: Two female pigs were used. After the insertion of a 9.5/11.5 ureteral access sheath, flexible ureteroscopy and laser lithotripsy for one hour were conducted. A TFL laser with a 200-µm fiber was used. The power setting used was 8 W (0.5 J × 16 Hz). A K-type thermocouple was inserted and fixed in the upper calyx of the right porcine kidney to record the temperature in the pelvicalyceal system during the laser activation. Second-look flexible nephroscopy followed by nephrectomy and pathohistological evaluation of the operated kidney was performed one week after the procedure in the first pig and 2 weeks after the surgery in the second pig. Results: Flexible nephroscopy did not reveal significant differences between the 2 porcine kidneys. Nevertheless, the histopathological report demonstrated severe alterations in the kidney of the first pig. Mild changes were reported in the kidney of the second pig. A significant improvement in inflammation and haemorrhagic lesions was demonstrated when comparing the 2 kidneys. Conclusions: The difference demonstrated between the 2 kidneys based on the histopathological report shows that the healing process is capable of improving severe to mild alterations within a one-week time frame. Two weeks after the surgery, only minor changes were observed, suggesting that even temperature increases above the threshold can be tolerated regarding renal damage.

11.
J Endourol ; 37(3): 273-278, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36274228

RESUMO

Purpose: To evaluate the feasibility and intraoperative technical parameters of the new robot-assisted surgical system Avatera by performing bilateral nephrectomy in a live porcine model. Materials and Methods: Six pigs underwent bilateral robot-assisted radical nephrectomy using the Avatera robotic system (RS). The operations were performed by experienced open (Group 1) and laparoscopic (Group 2) surgeons. The operating time, docking time, set-up time, and console time were evaluated. Data regarding intraoperative complications (major or not), injury of adjacent organs, and technical difficulties during the operation were also recorded. Results: Robot-assisted bilateral nephrectomy was completed effectively in all sample pigs. The docking time and set-up time were similar among the two groups, whereas the console time and operating time were significantly longer for the open surgeon group. Two intraoperative minor complications occurred in the open surgeon's group. An inadvertent damage of the renal vein occurred in two cases and the bleeding was controlled effectively. Other than the initial two cases, the estimated blood loss was <50 mL in both groups. Injury of the adjacent organs was not noticed. Conclusions: The study demonstrated that radical nephrectomy using the Avatera robotic surgical system is technically feasible, safe, and valid in pigs. Our results warrant the application of the Avatera RS in other urologic procedures, collecting data for further clinical trials.


Assuntos
Laparoscopia , Procedimentos Cirúrgicos Robóticos , Robótica , Urologia , Suínos , Animais , Estudos de Viabilidade , Nefrectomia/métodos
12.
World J Urol ; 41(2): 581-587, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36547678

RESUMO

PURPOSE: To evaluate the effectiveness and safety of non-papillary prone PCNL for the treatment of patients with renal abnormalities. METHODS: An observational retrospective cohort study including PCNL cases of patients with renal abnormalities was performed. The following inclusion criteria were applied: renal stones > 1.5 cm with maximal diameter, anatomical malformations of affected kidney (malrotated kidneys, horseshoe kidneys and kidneys with complete duplicated systems, medullary sponge kidney), patients treated with standard (30Fr) PCNL or mini-PCNL (22Fr). The lithotripsy was performed using the Lithoclast Master or the Lithoclast® Trilogy (EMS Medical, Nyon, Switzerland). RESULTS: Overall, 57 patients, 35 males, and 22 females with any renal malformation underwent non-papillary prone PCNL. Our study included 25 patients with horseshoe kidneys, 21 with malrotated kidneys, 9 with kidneys with duplicated pelvicalyceal systems and 2 with medullary sponge kidneys. The mean cumulative stone size was 36 ± 1.4 mm and most of the stones were in the lower calyceal group (36.9%) and in the pelvis (27.2%). The stone-free rate (SFR) was 84.2% and the mean hospitalization time was 2.7 ± 0.7 days. In total, postoperative complications were developed in six patients (10.5%), half of them presenting fever and the other half requiring blood transfusion (Grade II). CONCLUSION: The PCNL is the method of choice for treating large stones in anomalous kidneys. The generally accepted panacea that only a papillary puncture is safe is questioned by our results. Based on our experience, a non-papillary puncture proved to be a safe and effective procedure.


Assuntos
Rim Fundido , Cálculos Renais , Nefrolitotomia Percutânea , Nefrostomia Percutânea , Masculino , Feminino , Humanos , Estudos Retrospectivos , Nefrostomia Percutânea/métodos , Rim/anormalidades , Resultado do Tratamento
13.
World J Urol ; 41(2): 477-482, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36577927

RESUMO

PURPOSE: To investigate the feasibility of the avatera system for performing robot-assisted radical cystectomy (RARC) followed by intracorporeal reconstruction of ileal neobladder. METHODS: Six anesthetized female pigs were used to perform RARC and formation of the intracorporeal orthotopic ileal neobladder. Three surgeons with different level of expertise in the use of robotic systems performed RARC after a short instructional lecture and a 2-h hands-on training. The urinary diversion phase was performed only by the experienced surgeon. The successful completion of the procedure, operative time for demolitive and reconstructive phases, intraoperative blood loss and malfunction of the robotic system were evaluated. RESULTS: An improvement of the operative time was observed for each surgeon. The experienced surgeon, the fellow and the resident improved their time by 11, 15, and 22 min, respectively, between the first and the second RARC performed. The most significant time difference was demonstrated by the resident, who had no previous experience in using robotic systems. The time difference between the first and the last orthotopic ileal neobladder creation for the experienced surgeon was 51 min. CONCLUSION: The feasibility of avatera system for performing complex surgical procedure such as RARC with intracorporeal neobladder formation was demonstrated by this experimental study. No major bleeding or severe malfunctions were observed during the procedures. Significant improvement in operative time was demonstrated with the increasing experience from 1st to 6th case.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Neoplasias da Bexiga Urinária , Derivação Urinária , Feminino , Animais , Suínos , Cistectomia/métodos , Neoplasias da Bexiga Urinária/cirurgia , Estudos de Viabilidade , Resultado do Tratamento , Derivação Urinária/métodos , Procedimentos Cirúrgicos Robóticos/métodos
14.
Urolithiasis ; 51(1): 18, 2022 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-36534198

RESUMO

To evaluate the effect of different ureteroscope positions, saline pumping frequency, laser fiber diameter and ureteral access sheath (UAS) on outflow rate during flexible ureteroscopy (fURS). This study was performed in an anesthetized porcine model. The fURS setup included a manual pumping system, a 9.5 Fr single used-digital flexible ureteroscope and a ureteral access sheath (UAS). Outflow was collected and measured from the UAS during 1 min in all experimental settings. The evaluated variables were the position of the ureteroscope, the pumping frequency (2 s, 3 s or 5 s), the diameter of the used UAS (12/14 Fr or 14/16 Fr) and laser fiber (200 µm or a 272 µm). Ureteroscope position in the lower calyx was associated with significantly lower outflow rate (p < 0.05). The use of the 14/16 Fr UAS resulted in improved flow in the renal pelvis and upper calyx (p < 0.05) but not in the lower calyx. The use of a 200 µm laser fiber only improved flow in the upper calyx and when a 14/16 Fr UAS was being used. Pumping frequency did not show a significant correlation with outflow rate. The ureteroscope positioning and UAS size were important determinants of outflow rate through the UAS during fURS, while laser fiber diameter had a limited effect. In the lower calyx the outflow was minimal and was not improved by using a larger UAS.


Assuntos
Cálculos Renais , Ureter , Suínos , Animais , Ureteroscópios , Ureteroscopia/métodos , Pelve Renal
15.
Urolithiasis ; 50(5): 613-618, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35771241

RESUMO

To compare the effect of MOSES™ modulation technology to conventional pulse delivery technology on the irrigation fluid temperature (IFT) under different irrigation conditions during flexible ureteroscopy (FURS) in a live-anesthetized porcine model. For this experiment was used one female pig. A percutaneous access was obtained and a 30Fr sheath was placed inside the upper calyceal system. A thermocouple was inserted through the sheath to the upper calyx to record the effect on IFT during FURS. A Lumenis 120H Ho:YAG laser was used and the IFT was recorded during laser activation for 30 s at a laser power of 20 W, 40 W and 60 W under gravity and manual pump irrigation using MOSES™ and conventional pulse delivery technology. In the highest power settings the maximum IFT was achieved in 18 s under gravity irrigation (66.4 °C). It seems that there is no significant difference on IFT between MOSES and conventional mode on the IFT under different irrigation conditions during FURS at 20 W, 40 W and 60 W power settings. Furthermore, our results indicate that under manual pumping even high-power settings (40 W, 60 W) can be performed with safety. In the in vivo model, the MOSES™ pulse delivery technology does not have a significant difference in the maximal IFT in comparison to conventional pulse delivery technology during FURS in the same power settings. Manual pumping should be used to keep the IFT within safe limits.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Animais , Feminino , Temperatura Alta , Litotripsia a Laser/métodos , Suínos , Tecnologia , Temperatura , Ureteroscopia
16.
Curr Opin Urol ; 32(4): 393-396, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35749785

RESUMO

PURPOSE OF REVIEW: The puncture technique and site of the puncture can impact the clinical outcome and the development of postoperative adverse events following percutaneous nephrolithotomy (PCNL). The aim of the current review was to discuss the available puncture guidance approaches and outline the potential role of the recently introduced electromagnetic-guided method. RECENT FINDINGS: The puncture and PCNL tract establishment is usually performed using fluoroscopic or ultrasound guidance or a combination of two approaches. Electromagnetic-guided puncture is one of the most recent advancements of technology. The puncture navigation to the renal collecting system is available after placing a special wire with an electromagnetic tracking sensor into the desired calyx through the flexible ureterorenoscope. The available experimental and clinical studies have shown a high first puncture rate, decreased median time for obtaining a puncture, and shorter learning curves for beginners. SUMMARY: Fluoroscopic and ultrasound guidance are the main approaches used by urologists. However, these modalities require a steep learning curve, approximately 60 cases for reaching competency. The initial data on electromagnetic navigation have shown the feasibility and potential promising outcomes of this novel approach. New studies are required to investigate its potential implementation opportunities in the daily practice of urologists.


Assuntos
Cálculos Renais , Nefrolitotomia Percutânea , Nefrostomia Percutânea , Fenômenos Eletromagnéticos , Humanos , Rim/cirurgia , Cálculos Renais/cirurgia , Nefrolitotomia Percutânea/métodos , Nefrostomia Percutânea/métodos , Punções
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...